Series 9600 Oxygen and Carbon Dioxide Monitor




System Description

The Series 9600 Oxygen and Carbon Dioxide Analyzer is designed to provide continuous, unattended monitoring of both oxygen and carbon dioxide. The focal point of the Series 9600 is its state-of-the-art sensor technologies. The oxygen sensor is an extended life electrochemical sensor with EES (enhanced electrolyte system). This sensor provides exceptional accuracy and stability. EES retards passivation of the sensor anode by allowing the products of oxidation to dissolve in the electrolyte. In effect, the sensor is renewed continuously resulting in a significant increase in sensor life. In addition, the enhanced mechanical design of the sensor helps to ensure long life and virtually eliminates leakage of electrolyte, a nagging (and expensive) problem associated with other types of sensors.

Alpha Omega Instruments has complemented its oxygen measuring capabilities with a next generation NDIR (non-dispersive infrared) sensor. The carbon dioxide sensor incorporates closed-loop control for enhanced long-term calibration stability. The control signal is generated by means of an optical referencing element that monitors source intensity. This methodology, coupled with a novel source homogenizing gas sampling chamber, yields a system with greatly improved tolerance to changes in the infrared source outputs.

Specifications


OXYGEN
Ranges:
  • Percent: 0-100
Error Band: ± 1% of full scale
Response Time: 90% of full scale in < 20 seconds
Sensor Type: Long-life Electrochemical Sensor with EES
Operating Humidity Range: 0-99% RH non-condensning
Gas Sample Connections: 1/4" SS compression fitting
Sample Delivery: Pressurized sample or optional pump
Alarm Relays: Two (2) SPDT Form C contacts rated 10 A (250 VAC) / 5A (100 VDC) User configurable to alarm on either O2 or CO2 levels
Display: 4 line x 20 character LCD for both O2 and CO2
Analog Outputs: Two 4-20 mADC outputs that are range configurable. Either or both outputs can be set to provide 0-20 mADC
CARBON DIOXIDE
Ranges:
  • Percent: 0-20%
  • Trace: 0-5,000 Parts Per Million (PPM)
Error Band:
  • Percent Range: 0.1% or ± 5.0% of reading, whichever is greater
  • Trace Range: ± 30 ppm or ± 2% of reading, whichever is greater (error stated at 77°F and 14.7 psig)
Response Time: <35 seconds to 63% of step change @ a sample flow rate of 200ml/minute (recommended sample flow rate)
Sensor Type: Non-dispersive infrared (NDIR)
Operating Humidity Range: 0-99% RH non-condensing
Gas Sample Connections: 1/4" SS compression fitting
Sample Delivery: Pressurized sample or optional pump
Alarm Relays: Two (2) SPDT Form C contacts rated 10 A (250 VAC) / 5A (100 VDC) User configurable to alarm on either O2 or CO2 levels
Display: 4 line x 20 character LCD for both O2 and CO2
Analog Outputs: Two 4-20 mADC outputs that are range configurable. Either or both outputs can be set to provide 0-20 mADC
GENERAL SPECIFICATIONS
Power Requirements: 90-264 VAC, 50-60 Hz
Ambient Temperature Range: 40-100°F (5-38°C)
Sample Pressure Limits: <2.0 psig.
Enclosure: NEMA 1, Power coated, painted aluminum enclosure suitable for bench-top use
Enclosure Dimension: 10.76" W x 6.3" H x 13.10" D
Warranty: Two years electronics and sensors
Weight: <10 pounds (uncrated)